🚚 Free delivery from £99 of purchase

Mercurochrome Nasal spray + 2 replacable nozzles

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 142.71ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
£14.39
Mercurochrome Nasal spray + 2 replacable nozzles
Mercurochrome Nasal spray + 2 replacable nozzles
Description Our selection Customer reviews

MERCUROCHROME
Nasal Shower
Rhinosinusitis and allergic rhinitis
Daily cleaning of nasal cavity
Ergonomic
Medical device
Contains 1 nasal spray and 2 tips (adult + child)

Mercurochrome Nasal Bath is intended for a daily nose cleaning.
Optimal treatment for rhinosinusitis and allergic rhinitis.
Simply fill it in with a saline solution, position according to the instructions and rinse your nose.
Thanks to its two mouthpieces, adult and child, suitable for the entire family.
Can be used once or twice a day depending on your needs.

- Extra treatment of rhinosinusitis and allergic rhinitis
- Daily cleaning of the nasal cavity
- Ergonomic
Contains 1 unit and 2 interchangeable tips.

REF:
3160920504761

The composition may be subject to variations, so we advise you to always check the list on the purchased product.

Model: NI-001. Capacity: 300ml. The main components of this product are made of polymeric materials and consist of a bottle body, a pipe, a gasket and two flush ports (one adult port, one child port).

1. Strictly follow the instructions for use of the product.
2. Any use of the product on children under 12 years of age must be carried out under medical or parental supervision.
3. Do not talk or breathe through the nose when rinsing (so as to avoid coughing).
4. Do not use if you have an ear infection. Do not use if one or both nostrils are completely congested.
5. Rinse tips are personal hygiene products and are not interchangeable with other products.
6. This product may only be used with isotonic saline (i.e. a concentration of sodium chloride
of 0.9%).
7. Do not use this product if it is damaged (bottle, tip, seal, tube, etc.).
8. Any serious incident related to this product should be reported to the manufacturer, Laboratoires Juva Santé and the Agence Nationale des Produits de Santé (ANSM). This product should be stored in a cool, dry and well-ventilated place, away from direct sunlight and corrosive liquids or gases.
Shelf life: 3 years from the date of production.

Medical device. This medical device is a regulated health product and bears the CE mark under this regulation. March 2021.
Read carefully the product labeling and precautions for use before use. Manufacturer: Shenzhen Balinda Technology Co, Ltd

1. Before first use, rinse the components with sterile distilled water or with boiled and cooled water.
2. Select the appropriate flush tip: the 3 port tip for children 5-12 years or the single port tip for adults.
3. Fit the chosen tip to the tube and run a little saline through the assembly to flush it.
4. Before each use, flush these components (bottle, tip and tubing) with saline or boiled water.
5. Fill the bottle with saline (isotonic). It is recommended that the saline be heated to 36-38°C for optimum effect.
6. Place the seal on the bottle and then fit the tube with the nozzle.
7. 7. Check the temperature of the liquid before use by running a few drops over your hand (to avoid any risk of burning if heated too much). Position yourself for nasal rinsing: lean forward over a sink,
lower your head, tilt it slightly to the side, turn the bottle upside down
the bottle, insert the nozzle into the nostril, open the mouth slightly and breathe through
your mouth slightly and breathe through it (not through your nose), press the button at the bottom of the bottle to let the air in, and slowly inject the rinse solution into your nostril to start the nasal rinse.
8. When the rinse is complete, wipe your nose with a clean tissue or towel.
9. After each use: disassemble the device, empty the bottle of all remaining liquid, then rinse each part thoroughly with clean, warm water. Dry with clean absorbent paper or a clean, lint-free cloth. Store the product in a clean, dry place. Allow all materials to dry before reassembling the device.
10. Once a week, decontaminate the device by placing the components (without the seal) separately:
- Either in boiled water (maximum temperature 100°C - do not exceed this temperature)
- Or in 70° alcohol
And soak for 3 to 5 minutes, rinse (if the device has been decontaminated with alcohol) and dry each part.
For users requiring specific hygiene conditions, it is possible to perform this step 10 after each use.

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 18ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 126.1ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
THE #EASYPARA NEWSLETTER
Join our 100% beauty and well-being community to enjoy our latest news and exclusive offers, specially designed for you. We are there to be by your side!
First Name
Email
My items (0)